Veterinary Hematology Analyser
SPECIFICATION
Clinical Purpose | Veterinary Hematology Analyzers are used to count and characterize blood cells for disease detection and monitoring. Basic analyzers return a complete blood count(CBC) with a three-part differential white blood cell(WBC) or five part differential white blood cell(WBC) count.Sophisticated analyzers measure cell morphology and can detect small cell populations to diagnose rare blood conditions |
Type of Configuration | Benchtop |
Type of sampling system | Direct capillary sampling |
Type of operation | Fully automatic |
Compatible Species | Cat, dog, Rabbit, pig, goat, horse, monkey, +4 user defined |
Automatic Start Up,shut down and sample analysis | Yes |
Analysis principle | Electrical impedance, Calorimetry, Laser scattering method |
Type of cell counting | 5 part WBC differential |
Analysis parameter available | WBC, LYM#, MID#, GRA#, LYM%, MID%, GRA%, RBC, HGB, MCHC, MCH, MCV, RDW-CV, RDW-SD, HCT, PCT, MPV, PDW, PCT, P-LCR |
RBC histogram | Yes |
PLT histogram | Yes |
P-LCC histogram | Yes |
WBC histogram | Yes |
Minimum sample volume required µL | 9 |
Maximum sample volume needed in any of modes | 50 |
Throughput (samples per hour) | 60 |
Counting mode of the analyzer | Whole blood, peripheral and prediluted |
Time taken by the analyser to produce the test results(Analysis time) in seconds | 60 |
Capability to automatically enumerate, Nucleated Red Blood Cells in the CBC/ Difference Mode and without additional reagents | Yes |
Auto loader facility with mixer capable of loading min 90 samples at any time (with Open vial, Pre dilute & Closed vial modes) STAT capability with Positive Bar code identification facility for samples loading/unloading available | No |
Facility for User defined rules & flagging limits | Yes |
Facility for workload recording | Yes |
Have unlimited number of user-definable control files | Yes |
Quality assurance system with calibration and controls | Yes |
Quality control | X-R, L-J |
Type of Calibration | Automatic |
Automatic probe wipe | Yes |
Directly measures MCV | Yes |
Floating discriminator for WBC/PLT | Yes |
Linearity of Platelet in cells/microlitres | 0 to 2000 * 10³ cells/ micro litres |
Linearity of WBC in cells/microlitres | 0 to 3000 * 10³ cells/ micro litres |
Linearity of hemoglobin in gram per litre | 0 to 25 gm per litre |
Precision of WBC in % | 2.00% |
Precision of RBC in % | 1.50% |
Precision in HGB in % | <0.5% |
Precision of PLT in % | 3.00% |
Carryover of RBC,WBC,HGB,PLT in % | ≤1 |
Capability to differentiate between smaller RBCs and larger platelets | Yes |
Auto purge function in the analysers software | Yes |
Availability of Auto dilution | Yes |
Barcode reader facility for sample | Yes |
“Auto stop function in event of unacceptable control data” | Yes |
Analyses time for cytopenic samples | Yes |
Separate diluting nozzles for RBC and WBC | Yes |
Optimized reagents and controls | Yes |
Automatic electric clog removal | Yes |