| Purpose |
ECG machine is primary equipment to record ECG signal with interpretation which is required for recording and analyzing the waveforms with software. |
| Operating modes of ECG Machine |
Automatic, Manual and Rhythm |
| ECG machine should have ECG lead annotation facility |
Yes |
| Leads which is in ECG machine should be able to acquire simultaneously and interpret them |
12 |
| Number of channels |
3 |
| ECG machine should acquire lead ECG for both adult and paediatric patients |
Yes |
| The ECG machine should have facility to show lead fail indication |
Yes |
| The ECG machine should have facility to show lead reversal indication |
Yes |
| The ECG machine should have facility to show the impedance to quality check of connection |
Yes |
| Acquisition time for ECG Machine in sec |
10 sec |
| Digital sampling rate for Pacemaker spike detection |
8000 s/sec/channel |
| Recording of digital sampling for pacemaker |
500 s/sec/channel |
| ECG machine should have real time colour backlit display of ECG waveforms with signal qualify indication for each lead |
Yes |
| ECG machine should have frequency filters |
Artifact, AC and low and high pass frequency filters |
| Number of ECGs which can be store in ECG Machine |
50-99 |
| ECG machine should have full screen preview of ECG report for quality assessment checks prior to print |
Yes |
| Type of inbuilt screen |
LCD |
| Size of screen in inches |
0 |
| Display resolution of ECG machine in pixels |
640 x 480 |
| ECG machine should have interpretation facility of the amplitudes, duration and morphologies of ECG waveforms and associated rhythm for adult and pediatric patient |
Yes |
| ECG machine should have alphanumeric keyboard for patient data entry |
Virtual |
| Size of printing paper |
80mm x 20 mtr |
| Resolution of digital array printer using thermal sensitive paper in ECG Machine in dpi |
200 dpi x 500 dpi on 25 mm/sec speed |
| ECG machine report format |
Report formats of 3×4; 6×2, Rhythm for up to selected leads, 12 lead extended measurement, 1 minute of continuous waveform data for 1 selected lead |
| Provision of battery |
Yes |
| Battery capacity |
30 ECG or 30 minutes of continous rhythm recording on single charge |
| Connectivity to ECG Machine |
LAN |
| Storage on external portable memories |
USB support |
| The individual patient lead should be change without replacing the whole patient cable assembly |
Yes |
| Noise level in dba |
45 |
| Weight of ECG Machine in Kg |
2.5 |
| Frequency in Hz |
300 |
| Availability of latest interpretation software |
Yes |
| Wireless acquisition module with RF technology |
No |
| System should have the dedicated software to download the ECG form machine in PDF format |
Yes |
| Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) |
1 |
| User and service manual of ECG Machine |
Yes |