1 Channels ECG Machine
SPECIFICATION
Purpose | ECG machine is the primary equipment to record ECG signal with interpretation which is required for recording and analyzing the waveforms with software. |
Operating Modes of ECG Machine | Automatic, Manual and Rhythm |
ECG machine should have an ECG lead annotation facility | Yes |
Leads which is in the ECG machine should be able to be acquired simultaneously and interpret them | 12 |
Number of channels | 1 |
ECG machine should acquire lead ECG for both adult and paediatric patients | Yes |
The ECG machine should have the facility to show lead fail indication | Yes |
The ECG machine should have the facility to show lead reversal indication | Yes |
The ECG machine should have facility to show the impedance to quality check of connection | Yes |
Acquisition time for ECG Machine in sec | 10 sec |
Digital sampling rate for Pacemaker spike detection | NA |
Recording of digital sampling for pacemaker | NA |
ECG machine should have real time colour backlit display of ECG waveforms with signal qualify indication for each lead | No |
ECG machine should have frequency filters | Artifact, AC and low and high pass frequency filters |
Number of ECGs which can be store in ECG Machine | NA |
ECG machine should have full screen preview of ECG report for quality assessment checks prior to print | No |
Type of inbuilt screen | NA |
Size of screen in inches | 0 |
Display resolution of ECG machine in pixels | NA |
ECG machine should have interpretation facility of the amplitudes, duration and morphologies of ECG waveforms and associated rhythm for adult and pediatric patient | Yes |
ECG machine should have alphanumeric keyboard for patient data entry | Virtual |
Size of printing paper | 50mm x 20 mtr |
Resolution of digital array printer using thermal sensitive paper in ECG Machine in dpi | 200 dpi x 500 dpi on 25 mm/sec speed |
ECG machine report format | Report formats of 3×4; 6×2, Rhythm for up to selected leads, 12 lead extended measurement, 1 minute of continuous waveform data for 1 selected lead |
Provision of battery | Yes |
Battery capacity | 50 ECG or 1 hour of continous rhythm recording on single charge |
Connectivity to ECG Machine | NA |
Storage on external portable memories | NA |
The individual patient lead should be change without replacing the whole patient cable assembly | No |
Noise level in dba | 45 |
Weight of ECG Machine in Kg | 1.3 |
Frequency in Hz | 300 |
Availability of latest interpretation software | No |
Wireless acquisition module with RF technology | No |
System should have the dedicated software to download the ECG form machine in PDF format | No |
Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1 |
User and service manual of ECG Machine | Yes |