| Purpose |
ICU Bed are required to be used in Intensive Care Unit for comfort of Patient & facilitate comfortable transfer to & from Emergency/ OT/ Ward etc. & also to carry out point of care process including Radio-logical procedure at bed side |
| Type of ICU Bed Actuator |
Mechanical (Handle Operated) |
| Type of mechanism for functioning or controlling angular motion of bed part |
Super Smooth Crank Screw Mechanism |
| Type of mechanism for functioning or controlling Height of bed |
Super Smooth Crank Screw Mechanism |
| Number of section provided in Bed Top |
4 |
| Base frame and support frame should be fabricated using metallic square / rectangular section of adequate cross section and thickness to provide high structural strength and stability |
Yes |
| Bed top perforated |
Yes |
| Bed should have radio translucent top (X-Ray translucent) |
Yes |
| Availabilty side panel/Side safety guard |
Yes |
| Type of side panel |
Collapsible type |
| Number of Side panel |
2 |
| Availability Head & Foot panel/Board |
Yes |
| Shape of Head & Foot panel /Board |
C-type |
| Type of Head & foot Panel |
Detachable type |
| Material of head and foot panel |
ABS (acrylonitrile-butadiene styrene) |
| Availability of good grip for head/foot or side panel |
Yes |
| Slots for IV rod at four corners provided |
Yes |
| Number of hooks provided in IV rod |
4 |
| Availability of rectangular telesccopic tube box housing for tension spring |
NA for Super Smooth Crank Screw Mechanism & Hydraulic mechanism for height |
| Degree Angle & Height indicator shall be provided at both foot & head side |
Yes |
| X-Ray film holder used from |
Both side |
| Type of X-Ray Film holder |
Cassettle Based System |
| Power of motor in HP(for non motorized put NA) |
N/A |
| Better quality bearing should be used |
Yes |
| Avaiability of patient constraint belt provided on both side of bed |
No |
| Availability of Noiseless, non rusting swivel castor wheel/ roller with for easy Mobility & Steering |
yes |
| Facility of braking and locking mechanism provided in castor roller |
Yes |
| Number of caster to which braking system provided |
2 |
| Availiability Corner buffer in all four corner to protect patient from collision shock |
Yes |
| Safe working load capacity of ICU bed in kg |
200 |
| Facility of instant non powered/mechanical CPR( Cardiopulmonary Resuscitation) release at the head end for emergency |
Yes |
| Lilen Holder/Urine Bag holder provided |
Yes |
| Accessory Rail Provided at all four side of bed |
Yes |
| Mattress provided with ICU bed |
Yes |
| ICU mattress must X-ray translucent |
Yes |
| Mattress foam of the Bed should be with Anti Microbial agent incorporated into all components that assists in Prohibiting growth of bacteria & fungi and easy to clean |
Yes |
| Mattress shall be made of High resilient & bio-density foam |
Yes |
| Mattress should be translucent to allow radiography using portable X-ray machines |
Yes |
| Mattress should be made in cube cut design & independent cubes promote air flow to reduce moisture |
Yes |
| Material for ICU Bed Mattress |
PU Foam |
| Maximum thickness of Mattress in mm with tolerance of ± 2 mm |
100 |
| Approx foam Density for Head/sacrum in kg/m3 tolerance |
40 |
| Approx foam Density for Heel in kg/m3 |
30 |
| Therapeutic Weight limit for mattress in kg |
150 |
| Operating temperature & humidity for ICU bed |
10 -40 Deg C and relative humidity of 15-90% |
| Power Supply ( as appropriate fitted with Indian plug) |
N/A for mechanical operated |
| Facility of Resettable overcurrent breaker shall be fitted for protection |
Yes |
| ICU Bed frame and top must be Rust Proof |
Yes |
| Type of powder/Paint coating done to ICU Bed frame,top & side panel |
Epoxy Polyester Coating 50-60 microns |
| ICU Bed should be made up of high quality metal, pretreated with materials providing good finish, scratch resistant, bacteriostatic coating |
Yes |
| Process used for pre chemically treatment of metallic bed component |
Dip tank processes |
| Facility of easily cleaning /maintenance to ICU Bed |
Yes |
| Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) |
1 |
| Product instruction manual shall be supplied |
Yes |
| Standard Tool Kit for maintananace and Trouble Shooting to be provided with ICU bed |
Yes |
| Demonstration of working to be provided after completing supplies before Acceptance |
No demonstration provided |