Modular Cold Room with127.5 inches (L) x 81.5 inches (W) x 102 inches (H)

Make-PUTEX

Model-RT-243

SPECIFICATIONS

  • Area of cold room: 127.5 inches (L) x 81.5 inches (W) x 102 inches (H) or equivalent with internal
    temperature between 2°C to 8°CSupply and Installation of PUF Panels for walk in Chiller Room:- 60mm SS-304 Outside/SS-304
    inside, Insulation: -Rigid Poly urethane foam, Blowing agent: – Cyclopentane (Zero ODP and
    negligible GWP), Density:-40 ±2 Kg /Cu Mtr, Close Cell Content:-above 90%, Temp. Rang
    -30°C to 80°C, Thermal conductivity @ mean temperature of 23.9°C:- 0.021 – 0.023 W/mk, Fire
    Resistance:- Self
    Extinguishing Foam Water absorption (By volume):- <0.2 %,Compression strength @10%
    deformation:- 1.4 to 1.9 Kg./Sq. CM., Skin Thickness (Inner & Outer):
    0.4mm, Skin finish (Inner):- SS-304 Matt finish , Skin Finish (Outer) Pre-painted polyester sheet,
    Skin Colour:- RAL 9003,Skin Specification:- Pre-painted polyester sheet, 90 gsm zinc coating
    with outer coat of 70-100 microns, Environment acceptance:- UV Resistance pp sheet, Tensile
    strength :-270 to 410 MPa Adhesion strength (Foam to steel):-290 Kpa, Zinc coating details and
    thickness:- 90GSM Zinc coating (min), Any other Coating details:- Back coating liquid paint with
    primer
    60 mm Puf Door: –
    60mm Floor Puf (Floor Insulation): –
    60mm Puf Panels Density 40 +2 kg /Cu mtr /Close Cell Content:- above 90%, Temp. Rang
    30°C to 80°C, Thermal Conductivity @ a mean Temp of 23.9°C:- 0.021 – 0.023 W/mk, Fire
    Resistance:- Self Extinguishing Foam, Water absorption (By volume):- < 0.2 %, Compression
    strength @10% deformation:- 1.4 to 1.9 Kg./Sq. CM.,Skin Thickness (Outer):- 0.4mm, Skin Finish
    (Outer):- Pre painted polyster sheet, Skin Colour:- RAL 9003, Skin Specification:- Pre painted
    polyster sheet, 90 gsm zinc coating with outer coat of 70-100 microns, Environment acceptance:
    UV Resistance pp sheet, Tensile strength:-270 to 410 MPa Adhesion strength(Foam to steel):-290
    Kpa, Flooring :- 18 Gauge Stainless steel Sheet thickness (min), Any other Coating details:- Back
    coating liquid paint with primer, Skin thickness 18 gauge
    Supply and Installation Door for Chiller Room W-34″ X H-78″ 60mm Inside – SS-304/ Outside
    PPGI, Insulation: -Rigid Polyurethane foam Blowing agent: – Cyclopentane (Zero ODP and
    negligible GWP),Density:-40 +2 Kg /Cu Mtr, Close Cell Content:- above 90%, Temp. Rang:- –
    30°C to 80°C, Thermal Conductivity @ a mean Temp. of 23.9°C:- 0.021 – 0.023 W/mk, Fire
    Resistance:- Self Extinguishing Foam, Heavy duty Hinges with self-closing at 90°,Posi Seal door
    closure, “D’ type gasket & Door Sweeper gasket to prevent air leakages, Door Handle with locking
    arrangement, Safety release inside cold room.
    SITC of Refrigeration Units for New Chiller Room with Dual refrigerator system: –
    Evaporating Unit (IDU) (Ceiling mounted) Capacity:-1 S000BTU HR of each unit at Air Flow:
    T600 CFM, Air Trough:- 12 Rf, Refrigerant:- 404a CFC Free, Fan Motor:- 90 watt x 2Nos.,RPM
    1200,Expansion Valve:- Capillary, Coil Face area:- 0.37 Sq. Mtr.,No. of Rows :-3 (Inner grooved
    cOpper pipe tube for proper heat transfer), Fins :- Aluminum fins, FPI:- 8 fins per inch, IDU
    Enclosure; High thickness SS 304 body for robust structure, Removable side panel for easy service and minimum down time, Excellent corrosion resistance Condensing Unit (ODU)
    Capacity:- 12200 BTU/HR of each unit , Condenser coil(FTHX) :- Aluminum fins with inner
    grooved copper tube highly efficient in high ambient, Type of Compressor:- Hermetic
    reciprocating highly energy efficient, Compressor model:-KCMS11 CAL, Power Supply:
    220V/1 Ph/50Hz, fan motor power -75W, RPM ;- 900, Thermally Protected & permanently
    Lubricated fan motor, HP&LP protection ,Coil Face area :-0.37 Sq mt . , number of row :- 2 nos , Fins:- Aluminium fns FPI :- 14 fins per inch ,0DU Enclosure:- Powder Coated G.I. sheet to
    resist UV & Corrosion. Installation of Chiller room Puf panels, Door, Flooring, Refrigeration Unit
    with 30 Rft copper piping of each Unit, IDU to ODU cabling, Control wiring, N Testing, Vacuuming, Gas charging & Commissioning of system with High /1low temp alarm system, safety bell system.
    Supply, Installation Testing & Commissioning of Copper piping beyond 30 Ft (Each Unit.) 3/8, 1/2, as per site condition
    ” Controller: – Control panel with digital temp controller with Auto changeover facility with
    temperature and time basis
    Warranty: l years and AMC for 2nd and 3rd year from the date of installation
    Back up of spare parts and consumables: 10 years or more