Portable Ultrasound Machine
Model Number (P-23)
SPECIFICATION
COMPLIANCE YES /NO | |||
Product Description | Portable ultrasound scanners are commonly used for a wide range of point-of-care ultrasound (POCUS) applications. POCUS refers to the use of ultrasound by the treating physician or other care giver as opposed to the treating physician referring the patient to an ultrasound specialist. Unlike the comprehensive examinations performed by imaging professionals in radiology or cardiology settings, POCUS exams are typically performed to answer specific clinical questions. The use of ultrasound in the emergency department (ED) is a typical example of POCUS. | yes | |
UMDNS Code and names(Hint: This is for indicating the relevant universal medical devices nomenclature for the category of prouct ) | Scanning Systems, Ultrasonic, Portable ( 18-143) | yes | |
Scope of supply | Portable ultrasonic scanning systems provide two-dimensional (2-D) B-mode images of soft tissues without subjecting patients to ionizing radiation. It intends to primarily for abdominal, obstetric/gynecologic (OB/GYN), small-parts, and vascular imaging | yes | |
Transportability | The machine should be built like a laptop / integrated in a carrying case with a handle for transportation without a trolley. | yes | |
Types of Probes & Features | |||
Applications- Abdomen, abdominal vascular, urology, OB/GYN, neonatal brain, small parts (breast, thyroid, scrotal, prostate, MSK) | Yes | yes | |
High density more then 125 element probes in convex, TV & Linear | Yes | yes, 128 elements | |
Flat linear array | 5-10 MHz (±2) | yes | |
Convex array | 2.5-5 MHz (±2) | yes | |
4D Probe | No | no | |
Interoperative Probe | Yes | yes, hockey stick | |
More then 160 degree FOV TV probe | Yes | yes | |
Frequency Range of FOV TV | 4-9 Mhz | yes | |
Frequency Range of FOV TV | Yes | yes | |
Biplane trans rectal | Yes | yes | |
Biopsy Guide | Yes | yes | |
Scanning Depth | ≥30cm | yes, 36cm | |
Frame per second in B Mode | 250 | yes | |
Frame per second in Color Mode | 40 | yes | |
Scan Modes | |||
Dual Imaging | Yes | yes | |
Quad Imaging | Yes | yes | |
Steer M Mode | Yes | yes | |
M Mode colour | Yes | yes | |
Power Doppler | Yes | yes | |
Directional Power Doppler | Yes | yes | |
PW | Yes | yes | |
Sample Volume | 0.5-20 mm | yes | |
CW | Yes | yes | |
HPRF | Yes | yes | |
TDI-Tissue doppler imaging | Yes | yes | |
Surface 3D rendering | Yes | yes | |
Digital Beam Forming | Yes | yes | |
B-steer | Yes | yes | |
THI | Yes | yes | |
Duplex | Yes | yes | |
Triplex | Yes | yes | |
Speckle Reduction Imaging | Yes | yes | |
Compounding Imaging | Yes | yes | |
IMT -Intemal median thickness sw | Yes | yes | |
Autotrace & Measurement | Yes | yes | |
Panoramic Imaging | Yes | yes | |
Trapezoidal Imaging | Yes | yes | |
Gray Scale | 256 | yes | |
Real-Time and Frozen Zoom | Yes | yes | |
Dynamic Range | 20~280 dB | yes | |
Gain | 0~255 | yes | |
Monitor Type | LED/LCD | yes | |
Monitor Size, inch | 15 | yes | |
DICOM 3 COMPLIANT | Yes | yes | |
Automated B-mode (2-D) image | Yes | yes | |
Transducer Socket | Yes | 2 | |
Gel Warmer | Yes | no, but external | |
DVD/CD Write | Yes | no, but external | |
Dicom Interfacability Dicom to PACS * | Yes | yes | |
Interfacability Dicom to RIS | Yes | yes | |
Cart / trolley from OEM with gel & transducer holde | Yes | yes, optional | |
USG system supplied should be upgradable to next generation system on site | Yes | yes | |
Resettable over current breaker shall be fitted for protection | Yes | yes | |
Back up time in minutes * | Yes | 120min | |
Yes | |||
Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | Yes | 2 years | |
Number of installations of the Portable USG machines in Central /State/PSU Govt Hospitals( Note: Seller should supply a performace certificate of the device to the buyer if demanded after placement of order) * | 0 | 0 | |
WEIGHT, kg (lb) without trolley | 8.5 KG | ||
Resettable over current breaker shall be fitted for protection * | yes | ||