| Clinical Purpose |
Veterinary Hematology Analyzers are used to count and characterize blood cells for disease detection and monitoring. Basic analyzers return a complete blood count(CBC) with a three-part differential white blood cell(WBC) or five part differential white blood cell(WBC) count.Sophisticated analyzers measure cell morphology and can detect small cell populations to diagnose rare blood conditions |
| Type of Configuration |
Benchtop |
| Type of sampling system |
Direct capillary sampling |
| Type of operation |
Fully automatic |
| Compatible Species |
Cat, dog, Rabbit, pig, goat, horse, monkey, +4 user defined |
| Automatic Start Up,shut down and sample analysis |
Yes |
| Analysis principle |
Electrical impedance, Calorimetry, Laser scattering method |
| Type of cell counting |
5 part WBC differential |
| Analysis parameter available |
WBC, LYM#, MID#, GRA#, LYM%, MID%, GRA%, RBC, HGB, MCHC, MCH, MCV, RDW-CV, RDW-SD, HCT, PCT, MPV, PDW, PCT, P-LCR |
| RBC histogram |
Yes |
| PLT histogram |
Yes |
| P-LCC histogram |
Yes |
| WBC histogram |
Yes |
| Minimum sample volume required µL |
9 |
| Maximum sample volume needed in any of modes |
50 |
| Throughput (samples per hour) |
60 |
| Counting mode of the analyzer |
Whole blood, peripheral and prediluted |
| Time taken by the analyser to produce the test results(Analysis time) in seconds |
60 |
| Capability to automatically enumerate, Nucleated Red Blood Cells in the CBC/ Difference Mode and without additional reagents |
Yes |
| Auto loader facility with mixer capable of loading min 90 samples at any time (with Open vial, Pre dilute & Closed vial modes) STAT capability with Positive Bar code identification facility for samples loading/unloading available |
No |
| Facility for User defined rules & flagging limits |
Yes |
| Facility for workload recording |
Yes |
| Have unlimited number of user-definable control files |
Yes |
| Quality assurance system with calibration and controls |
Yes |
| Quality control |
X-R, L-J |
| Type of Calibration |
Automatic |
| Automatic probe wipe |
Yes |
| Directly measures MCV |
Yes |
| Floating discriminator for WBC/PLT |
Yes |
| Linearity of Platelet in cells/microlitres |
0 to 2000 * 10³ cells/ micro litres |
| Linearity of WBC in cells/microlitres |
0 to 3000 * 10³ cells/ micro litres |
| Linearity of hemoglobin in gram per litre |
0 to 25 gm per litre |
| Precision of WBC in % |
2.00% |
| Precision of RBC in % |
1.50% |
| Precision in HGB in % |
<0.5% |
| Precision of PLT in % |
3.00% |
| Carryover of RBC,WBC,HGB,PLT in % |
≤1 |
| Capability to differentiate between smaller RBCs and larger platelets |
Yes |
| Auto purge function in the analysers software |
Yes |
| Availability of Auto dilution |
Yes |
| Barcode reader facility for sample |
Yes |
| “Auto stop function in event of unacceptable control data” |
Yes |
| Analyses time for cytopenic samples |
Yes |
| Separate diluting nozzles for RBC and WBC |
Yes |
| Optimized reagents and controls |
Yes |
| Automatic electric clog removal |
Yes |